Optimization of MRI Image Quality Through Slice Thickness Variations in AXIAL T2-Weighted Imaging Using Air™ RECON DL
Abstract
Magnetic Resonance Imaging (MRI) is a diagnostic imaging modality with excellent soft-tissue contrast. MRI image quality is influenced by several acquisition parameters, including slice thickness. AIR™ Recon DL (Deep Learning Image Reconstruction) has been developed to improve image quality through noise reduction and deep learning-based reconstruction. This study aimed to analyze the effects of slice thickness variation and AIR™ Recon DL level on the image quality of axial T2-weighted sequences acquired on a 1.5-Tesla MRI system. A quantitative experimental design using a phantom study was employed. Slice thicknesses of 1 mm, 3 mm, and 5 mm were evaluated at four AIR™ Recon DL levels: Off, Low, Medium, and High. Image quality was assessed using Signal-to-Noise Ratio (SNR) and Contrast-to-Noise Ratio (CNR), measured with the Region of Interest (ROI) method. Data were analyzed using the Shapiro–Wilk test, Two-Way Repeated Measures ANOVA, and post hoc testing. The results demonstrated that slice thickness, AIR™ Recon DL level, and their interaction significantly affected both SNR and CNR (p<0.001). SNR increased with greater slice thickness and higher AIR™ Recon DL levels, with the highest value observed at 5 mm and the High level. In contrast, CNR tended to decrease as both parameters increased, and the highest CNR was obtained at 1 mm with AIR™ Recon DL Off. These findings indicate that AIR™ Recon DL can effectively improve signal quality; however, protocol optimization should maintain an appropriate balance among signal enhancement, noise reduction, partial-volume effects, and image contrast. The findings may support optimization and clinical studies.
Keywords
Full Text:
full textReferences
D. W. McRobbie, E. A. Moore, M. J. Graves, and M. R. Prince, MRI from Picture to Proton, 3rd ed. Cambridge, U.K.: Cambridge Univ. Press, 2017.
C. Westbrook, C. K. Roth, and J. Talbot, MRI in Practice, 5th ed. Hoboken, NJ, USA: Wiley-Blackwell, 2019.
M. A. Brown and R. C. Semelka, MRI: Basic Principles and Applications, 4th ed. Hoboken, NJ, USA: Wiley-Blackwell, 2011.
R. H. Hashemi, W. G. Bradley, and C. J. Lisanti, MRI: The Basics, 5th ed. Philadelphia, PA, USA: Wolters Kluwer, 2018.
A. M. S. A. Victor, G. N. Sutapa, A. A. N. Gunawan, I. N. Sandi, N. N. Rupiasih, and I. N. Simpen, "Optimasi slice thickness dengan nilai signal to noise ratio dan contrast to noise ratio untuk meningkatkan kualitas citra MRI genu," Kappa J., vol. 9, no. 1, pp. 72–77, 2025, doi: 10.29408/kpj.v9i1.29591.
M. Seo, K. J. Ahn, H. S. Lee, M. D. Nickel, J. Jang, Y. J. Huh, I. Shin, J. Y. Lee, and B. S. Kim, "Effects of deep learning-based reconstruction on the quality of accelerated contrast-enhanced neck MRI," Korean J. Radiol., vol. 26, no. 4, pp. 446–458, 2025.
K. F. Stupic et al., "A standard system phantom for magnetic resonance imaging," Magn. Reson. Med., vol. 86, no. 2, pp. 1194–1211, 2021, doi: 10.1002/mrm.28779.
Zana, "Pro-MRI V.10 phantom specifications," 2021.
R. D. Peters and S. Lawson, "AIR™ Recon DL for diffusion-weighted imaging: Technical white paper," GE Healthcare, 2021.
M. Kelly, A. Moran, and C. Saidlear, "Phantom-based assessment of a deep learning MR image reconstruction workflow to inform clinical protocol optimization," presented at Eur. Congr. Radiol. (ECR 2023), 2023, doi: 10.26044/ecr2023/C-23583.
T. J. Allen et al., "Evaluation of a deep learning reconstruction for high-quality T2-weighted breast magnetic resonance imaging," Tomography, vol. 9, no. 5, pp. 1949–1964, 2023, doi: 10.3390/tomography9050152.
American College of Radiology, Magnetic Resonance Imaging Quality Control Manual. Reston, VA, USA: ACR, 2015.
American College of Radiology, "Large and medium phantom test guidance for the MRI accreditation program," 2022.
C. C. Chen, Y. L. Wan, Y. Y. Wai, and H. L. Liu, "Quality assurance of clinical MRI scanners using ACR MRI phantom: Preliminary results," J. Digit. Imaging, vol. 17, no. 4, pp. 279–284, 2004.
Z. Chen et al., "Deep learning for image enhancement and correction in magnetic resonance imaging—State-of-the-art and challenges," J. Digit. Imaging, vol. 36, no. 1, pp. 204–230, 2023, doi: 10.1007/s10278-022-00721-9.
A. C. Epistatou, I. A. Tsalafoutas, and K. K. Delibasis, "An automated method for quality control in MRI systems: Methods and considerations," J. Imaging, vol. 6, no. 10, p. 111, 2020, doi: 10.3390/jimaging6100111.
J. Harkin and C. Ingham, "Comparison of SNR assessment techniques for routine multi-element RF coil QC testing," Phys. Imaging Radiat. Oncol., vol. 2, p. 100012, 2022.
S. Kiryu et al., "Clinical impact of deep learning reconstruction in MRI," Radiographics, vol. 43, no. 6, p. e220180, 2023.
N. Koonjoo, B. Zhu, G. C. Bagnall, D. Bhutto, and M. S. Rosen, "Boosting the signal-to-noise of low-field MRI with deep learning image reconstruction," Sci. Rep., vol. 11, p. 8248, 2021, doi: 10.1038/s41598-021-87482-7.
A. Nilsson, "Development of a phantom for optimisation and quality control in functional MRI (fMRI)," M.S. thesis, Lund Univ., Lund, Sweden, 2006.
E. K. Englund, M. C. Langham, J. A. Detre, and F. W. Wehrli, "Quantitative MRI: Principles and clinical applications," J. Magn. Reson. Imaging, vol. 52, no. 3, pp. 683–698, 2020.
J. Zhang, Y. Liu, and H. Wang, "Optimization of MRI acquisition parameters for improved image quality," Med. Phys., vol. 48, no. 8, pp. 4234–4245, 2021.
L. Wang, S. Kim, and J. Park, "Deep learning-based image reconstruction in MRI: A comprehensive review," IEEE Trans. Med. Imaging, vol. 42, no. 5, pp. 1234–1248, 2023.
R. Smith, A. Johnson, and M. Williams, "Phantom studies in MRI quality assurance: Current practices and future directions," J. Appl. Clin. Med. Phys., vol. 24, no. 2, pp. 45–58, 2023.
D. Lee, K. Park, and S. Choi, "Effect of slice thickness on image quality in 1.5T and 3T MRI systems," Korean J. Radiol., vol. 25, no. 3, pp. 312–320, 2024.
DOI: https://doi.org/10.32502/msj.v7i1.11425
Refbacks
- There are currently no refbacks.
Copyright (c) 2026 Ni Wayan Yuniarsih, Ni putu Rita Jeniyanthi, Dedy Rudy H Mantow
Medical Scientific Journal (MESINA) Published by Faculty of Medicine, University of Muhammadiyah, Palembang, South Sumatra. This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
________________________________________________
Medical Scientific Journal (MESINA)
Faculty of Medicine, University of Muhammadiyah Palembang
Jl. KH. Balqi Jl. Banten II, 13 Ulu, Kec. Seberang Ulu II, Palembang City, South Sumatera 30263
E-Mail: mesina@um-palembang.ac.id


